Tools for drippers and sprinklers installation
Consists of fan, foggers and controller. Nebulised water effectively mixes with air in assistance of fan and humidified air is distributed throughout the greenhouse. The moist air flow extends over a distance of up to 5 m. The controller allows to change the moisture mode by adjusting the time period and the water supply. Active humidifier equipped with 2 installed and a set of interchangeable foggers with flow 3, 4, 6 l/h, which allows to change the amount of water supplied to the spray from 3 to 12 l/h. The device can be used to adjust the climate in the greenhouse, humidity retention and is intended for olericulture and mushroom, as well as for the improved environmental conditions (temperature decrease) during the hot period in public places (cafes, gazebos, markets, etc.) Controller power supply - 220V. By special order it is possible the performance 24V.
Digital in/outdoor hygro-thermometer.For controlling temperature and humidity inside the greenhouse or outside, but the display is installed indoors, and the sensor can be removed outside with the cable which length is 1 m.Measuring humidity range: 10%RH - 99%RH, humidity accuracy: +-5%, humidity display resolution 1%RH.Measuring temperature range: -50оС till +70оС, temperature accuracy: +-1оС, temperature display resolution 0,1оС.Selectable temperature unit: оС or оF.Recording max/min temperature value automatically.Operating voltage: 1.5V.Dimensions: 100 mm х 20 mm х 110 mm.LCD dimensions: 80 mm х 60 mm.Attention: Please Protect the sensor device from falling water!
Drill model DR.Features:
Material: Hardened steel quality.
Hex head shape is suitable for all types of hand-held drills.
Rotation - clockwise.
The special shape of the drill enables easy and precise drill irrigation pipes to install start-connectors or saddles.
DR excellent drill.Benefits:
Easy to use - starts with a small diameter, increasing to a suitable diameter.
Very accurate hole.
With plug the holes do not go to the other side.
Inexpensive.Manufactured in different sizes:
7.5 mm, 8 mm, 8.5 mm;
12mm, 14mm, 15mm, 15.5 mm, 16 mm, 17 mm;
19 mm and 22 mm.
Drills special sizes can be made to order.
This instrument evaporates insecticide and anti-fungi material, dispersing it on and around the plants. It is most effective against Powdery Mildew, Thrips and Mites. This electric evaporator is a reluable unit with no moving parts. It is made from Alumimium which is non-corrosive. The unit includes a robust heating element, purposely designed for prolonged usage. Heating element comes with 5 year warranty. As the vaporized material is sulfur, which is ideal anti-fungi material. Evaporators are certified for organic cultivation.
Insert removable 3 mm for universal punch. Designed for punching holes for external drippers Clicktif.
Insert removable 4 mm for universal punch. Designed for punching holes for the plungers and external drippers Katif.
Insert removable for external dripper Clicktif - for universal inserter.
Insert removable for external dripper Katif - for universal inserter.
Insert removable for plungers - for universal inserter.
Mini Punch MP-3 MP-4 is designed for punching holes for mounting external droppers and plungers for Sprinklers in PE pipe.Mini Punch MP-3 with a diameter of 3 mm punch holes designed for outdoor dropper.Puncher (punch) is used to pierce holes in the plastic pipe or garden hose and subsequent pressing the plunger into the hole. Hole diameter - 3mm.Mini Punch MP-4 with a diameter of 4 mm punch holes designed for plungers for sprinklers and foggerov, as well as external drip model KATIF.
Ph meter (ph-01)
Pen-type ph meter
Specification
measure range: 0.00—14.00ph
resolution:0.01ph
accuracy:+/_0.01ph
Automatic temperature compensation: 0°C--60°C
Power supply: 2*1.5V(AG13 battery)
operating temperature: 0°C--60°C
calibration: manual at one point through trimmers
dimension: 155mm*29mm*16mm
weight: 48g
Operation
remove tne protective cap.
first rinse the electrode with distilled water, and suck it with filter paper.
turn the meter on by pressing the on key.
immerse the ph meter electrode in the solution to be tested.
stir gently and wait for the reading to stabilize.
after use. rise the electrode with water to minimize contamination. turn the meter on by pressing the off key.
always replace the protective cap after use.
Calibration
immerse the electrode in PH6.86(under the temperature of 25°C ) standard buffer solution of phosphate, and gently shake the electrode.
regulate the trimmer with a screwdriver until the buffer solution value corresponding to the measurement temperature is obtained.
immerse the electrode in ph 4.01 or ph 9.18 the standard buffer solution of borax.
after about one minute, until the buffer solution value corresponding to the measurement temperature is obtained.
Battery install
If the meter can not be switched on or the display fades, to change batteries, pull out the battery case and replace batteries. Pay attention to the polarity of battery.
Important : the instrument’s ph range must be re-calibrated whenever.
approximately one month has passed from the last calibration.
the electrode has been used in particularly taxing conditions.
the utmost accuracy is required.
Sprey Gan (1/4" FEMALE )Spear PVC reduces the weight and combined with a plastic nozzle makes the cost gun more accessible. To connect to a hose uses an internal thread 1/4 ".
Meter TDS & ECSpecificationLarge LCD screenLow power consumptionHigh accuracyLong battery lifemultifunctionalityUseful features:1. The device records the last testimony.2. After 5 minutes the automatic disconnection of the battery to store energy.conductivityTDSDegrees CelsiusAccuracyNWThe size0--9990us / cm0 - 5000ppm0,1 - 80,0 ° C± 2%55g154 * 30 * 14 (mm)Switching between TDS and conductivity:The default output data the TDS, if you want to measure the electrical conductivity of the solution ( EU ), press the SHIFT button.Automatic Temperature Compensation:The device has a function of automatic temperature compensation to the measurement mode.Temperature Output Format:Temperature readings are displayed by default in degrees Celsius. Double-click the SHIFT button to display the temperature in degrees Fahrenheit.Measuring the parameters of the solution:1. Remove the electrode protective cap before use.2. Press the button, place the electrode into the test solution.3. After the readings stabilize, press the button and holding it, remove the device from the solution and read the testimony.4. After reading and disconnection device wipe the electrodes and close the cap.Maintenance:Keep clean the electrodes, cover them with a protective cap for a long period of inactivity, remove the batteries from the device.Note:1. Device - is a professional tool, please operate according to instructions in order to avoid damage to the instrument2. Avoid direct sunlight.3. Use standard calibration buffer solution. Improper calibration will lead to measurement errors.4. Do not immerse the instrument in the test solution is completely in order to avoid short circuits.
Universal inserter UP-N is designed to insert external drippers and plungers in PE pipe with a diameter of 12 mm to 32 mm
Universal punch UP is designed to punch holes for mounting external drippers and plungers in PE pipe with a diameter of 12 mm to 32 mm